Press release: Statement from the Independent Expert Advisory Panel: 30 June 2017

image_pdfimage_print

The tests that are currently being conducted are a screening test to identify which Aluminium Composite Material (ACM) panels are of concern. It tests the filler – the core of the panel – to check if it is of limited combustibility (category 1) or not (category 2 or 3). This is in line with the requirement of the Building Regulations guidance. The filler is one element of the overall cladding system.

If the panel core fails the test we would expect the landlord to take the recommended interim fire safety measures issued on 22 June 2017.

The Panel will engage with experts across the country to consider whether these panels can be used safely as part of a wider building external wall system, and therefore could remain on a building under certain approved circumstances. If, in the meantime, a landlord chooses to take down and replace cladding, care should be taken to consider the impact that removal may have on the other wall elements, especially insulation, and therefore on the overall fire integrity of the building as well as other Building Regulation requirements.